sales@anhuitiankang-group.com
Home      Products     Cables     Special cable       High temperature and oil resistant speci
  • High temperature and oil resistant special cable

High temperature and oil resistant special cable

Resistance to high temperature oil special cable applies to the metallurgical, petroleum, chemical industry and power plants and other industrial and mining enterprises, under the condition of high temperature and harsh environment, such as acid, alkali, oil and water temperature conditions) for all kinds of electrical, instrumentation and automation of cable, for ac rated voltage up to and including 450/750 v control, circuit monitor and protection and situations. Ii. Model and Name:

The serial number model The name of the
1 KFF Fluoroplastic insulated and sheathed control cable
2 KFFP Fluoroplastic insulated and sheathed control cable
3 KFFR Fluoroplastic insulated and jacketed control flexible cable
4 KFFRP Fluoroplastic insulated and sheathed control flexible cable
5 KFV Fluoroplastic insulated PVC sheathed control cable
6 KFVP Fluoroplastic insulated PVC sheathed control cable
7 KFVR Fluoroplastic insulated PVC sheathed control flexible cable
8 KFVRP Fluoroplastic insulated PVC sheathed control flexible cable
9 KFV22 Fluoroplastic insulated PVC sheathed steel tape armored control cable
10 KFVP22 Fluoroplastic insulated PVC sheathed steel tape armored shielded control cable
11 KFVR22 Fluoroplastic insulated PVC sheathed steel tape armored control flexible cable
12 KFVRP22 Fluoroplastic insulated PVC sheathed steel tape armored control flexible cable
13 KFFV22 Fluoroplastic insulated and inner sheathed PVC outer sheathed steel tape armored control cable
14 KFFRV22 Fluoroplastic insulated and inner sheathed PVC outer sheathed steel tape armored control flexible cable

Rated voltage: AC Uo/U; 2. Operating temperature: No. 1 ~ 4-60 ~ +200℃ No. 5 ~ 14-15 ~ +105℃ 3, insulation resistance (20℃) not less than 50M ω ·km 4, conductor core DC resistance (20℃) in accordance with GB3956-97 5, unarmored cable bending radius not less than 6 times of cable diameter, The bending radius of armored cable is not less than 12 times of cable diameter. 6, low installation and laying temperature: No. 1 ~ 4-45 ℃ No. 5 ~ 140 ℃

The serial number Nominal cross section Conductor core specification Conductor core specification Some cable
The serial number
One, two, five, six, nine, ten, thirteen
The serial number
3,4,7,8,11,12,14
The serial number
1 ~ 4
The serial number
Five to eight
The serial number
9 ~ 14
1
2
3
4
5
0.2
0.5
0.75
1.0
1.5
2.5
1/0.52
1/0.80
1/1.0
1/1.13
1/1.38
1/1.76
7/0.20
16/0.20
19/0.23 24/0.20
19/0.26 32/0.20
19/0.32 30/0.25
49/0.26
2 ~ 44
2 ~ 30
2 ~ 19
2 to 16
2 ~ 14
2 ~ 8
2 ~ 61

7 ~ 37
7 ~ 37
7 ~ 37
4 ~ 37



INQUIRY

Email