I. Instrument overview:
Hot jacket bimetal thermometer is a kind of field measuring instrument suitable for medium and low temperature measurement, can be used to directly measure the temperature of gas, liquid, and steam. The thermometer is waterproof, corrosion-proof, flameproof, shock-resistant, intuitive, easy to read, no mercury damage, durable and so on. Can replace other shape measuring instrument.
2. Measurement principle:
It works on the principle that two different metals expand differently when the temperature changes. The main component of industrial bimetal thermometers is a multi-layer metal sheet composed of two or more metal sheets stacked together. In order to improve the temperature sensitivity of bimetal thermometers, metal sheet is usually made into spiral coil shape. When the temperature of the multilayer metal sheet changes, the expansion or contraction of the metal layer is not equal, causing the spiral coil to roll or loosen. Because one end of the spiral coil is fixed and the other end is connected to a freely rotating pointer, the temperature can be indicated on a circular indexing scale when the bimetallic sheet senses a change in temperature.
3. Applicable occasions:
It can cooperate with all kinds of casing installation to meet the requirements of different pressure levels. It can directly measure the temperature of liquid, vapor and gas media and solid surface in the range of -80-+500℃ in various production processes.
4. Performance characteristics:
1, the field display temperature, intuitive and convenient, safe and reliable, long service life and other features.
2, no mercury damage, easy reading, strong earthquake resistance.
3, the protection pipe is 1Gr18Ni9Ti stainless steel and molybdenum titanium, pressure, corrosion resistance.
4. Core-pulling thermometer can be maintained or replaced without shutdown for a short time.
Five, technical indicators:
Execution standard
JB/T8803-1998 GB3836-83.
The other parameters
Nominal diameter of dial: 60,100,150;
Accuracy grades :(1.0), 1.5;
Thermal response time: ≤40S;
Protection class: IP55;
Angle adjustment error: Angle adjustment error should not exceed 1.0% of its range;
Return error: bimetal thermometer return error should not be greater than the basic error limit * value;
Repeatability: the limit range of repeatability of bimetal thermometers should not be greater than 1/2 of the value of the basic error limit *.
Six, notes
1, can not directly twist the head;
2, length to choose close to the standard size (integer multiple of 50mm);
3. The length of the protective tube immersed in the measured medium shall be greater than that of the temperature sensing element. Generally, the immersion length is recommended to be greater than 100mm, and the immersion length of 0-50℃ range is recommended to be greater than 150mm to ensure the accuracy of measurement.
4, bimetal thermometer should not be used to measure the temperature of the medium in the open container.
5, in the storage, use of installation and transportation, should avoid collision protection tube, do not make the protection tube bending, not to use the table as a wrench.
6, in the case of normal use should be regular inspection. Generally every six months is appropriate.
7, do not allow to work in strong vibration environment, so as not to shadow the life of bimetal, electrical contact bimetal thermometer is not allowed to be used in the control loop of large vibration occasions, so as not to affect the reliability.
Seven, temperature range:
Measuring range ℃ |
Scope of application |
|
Industry, commerce |
Laboratory, small scale |
|
- 80 ~ + 40 |
Square root |
Square root |
- 40 ~ + 80 |
Square root |
Square root |
0 ~ 50 |
Square root |
Square root |
0 ~ 100 |
Square root |
Square root |
0 ~ 150 |
Square root |
Square root |
0 ~ 200 |
Square root |
Square root |
0 ~ 300 |
Square root |
Square root |
0 ~ 400 |
Square root |
Square root |
0 ~ 500 |
Square root |
Square root |
Viii. External Dimensions:
form |
D |
A |
B |
E |
d |
The radial type |
105 |
23 |
73 |
|
Ф 8 Ф 10 |
155 |
23 |
73 |
|
||
The axial type |
65 |
50 |
110 |
34 |
|
105 |
50 |
110 |
34 |
||
Universal type |
105 |
23 |
178 |
120 |
|
155 |
23 |
178 |
120 |
||
Electric contact The axial type |
128 |
40 |
135 |
|
|
Electric contact The radial type |
128 |
72 |
150 |
42 |
|
Electric contact Universal type |
128 |
40 |
175 |
98 |
Ix. Model and Specification:
Type no. |
Temperature measurement range |
Precision grade |
Protective tube material |
Gauge, |
Nominal pressure |
Casing form |
WSS-403S |
- 80-40 + - 40 - + 80 0 to 50 0-100. 0-150. 0-200. 0-300. 0-400. 0-500. |
1, 5 |
1Cr18Ni9Ti
304 316 316L Hartz C - 276 |
75 100 150 200 300 |
30 mpa or less |
Threaded connection |
WSS-503S |
||||||
WSS-413S |
||||||
WSS-513S |
||||||
WSS-483S |
||||||
WSSX-413S |
||||||
WSSX-483S |
||||||
WSS-403L |
150-40MPa |
Flanged connection |
||||
WSS-503L |
||||||
WSS-413L |
||||||
WSSX-503L |
||||||
WSS-483L |
||||||
WSS-583L |
||||||
WSSX-403L |
||||||
WSSX-483L |
Note: Bimetal thermometers can be equipped with various installation sleeves, see the form of thermal installation sleeves; The rest of the protective tube materials are ordered according to the agreement: * indicates the nominal pressure according to the flange pressure grade.