Local temperature display adopts imported chip assembly with high precision, high stability, error ≤0.5%, internal power supply, micro power consumption, stainless steel shell, strong protection, beautiful and delicate. The local temperature display adopts imported high precision, low temperature drift, ultra-low power integrated circuit and wide temperature type LIQUID crystal display. The built-in high energy battery can work continuously for more than 5 years without laying power supply cable. It is a new type of field temperature display with high precision, good stability and strong applicability. It is an ideal substitute for traditional field pointer bimetal thermometer. Measuring range: PT100-50 ~ 600℃; K type 0~1100℃ sensor: Pt100 (Class A, CLASS B), K type (class I, class II) accuracy: 0.5%±1 word (Pt100); Sampling time: 1-5 seconds Display: 3-bit LCD power supply battery: one built-in 3.6V/2.4Ah industrial lithium battery, continuous use ≥3 years Environmental conditions: Temperature: -20~70℃ Humidity: 90%RH Connection thread: Shell material: 1Cr18Ni9Ti panel: glass + INNER PVC mask outer tube material: 1Cr18Ni9Ti Local temperature display selection table
Spectrum code |
Code instructions |
||||||||||
|
Local temperature display device |
||||||||||
Watchcase material |
-A |
Stainless steel case |
|||||||||
-B |
Aluminum alloy shell (flameproof digital display) explosion-proof certificate No. : CNEx14.3416 |
||||||||||
-100B |
Polyester shell |
||||||||||
Accuracy of measurement |
1 |
1% |
|||||||||
0 |
0.5% |
||||||||||
Temperature sensor |
P |
Pt100 |
|||||||||
K | Type K thermocouple | ||||||||||
Remote resistance sensor |
0 |
No PT100 remote signal output |
|||||||||
P |
With Pt100 remote signal output (stainless steel or cast aluminum case only) |
||||||||||
Measuring range |
S |
-50~200,0~300~600℃,0~1100℃ select the appropriate temperature range |
|||||||||
Structure form |
0 |
Axial (for stainless steel case) |
|||||||||
1 |
Radial (cast aluminum and polyester case only for radial construction) |
||||||||||
8 |
Universal type (suitable for stainless steel watchcase straight rod access) |
||||||||||
Sensor type |
Y |
Lead access head (suitable for stainless steel case axial and radial, cast aluminum and polyester case radial, suitable for normal temperature within 200℃) |
|||||||||
G |
Straight rod access meter head |
||||||||||
Interface form with user side installation |
0 |
Unthreaded or flanged connection (plain rod) |
|||||||||
M |
Thread connection (specify thread size) |
||||||||||
F |
Flange connection (indicate flange size) |
||||||||||
Z |
The user specifies the installation mode |
||||||||||
Lead length (mm) |
- |
Suitable for sensor form Y |
|||||||||
Insertion depth (mm) |
- |
Length of probe rod (including thread length for threaded connection, below flange length for flange connection) |
Name: local temperature display, stainless steel case, accuracy 0.5, PT100 sensor, no far-spread resistance signal output, temperature range: -50~100℃, meter head universal, straight rod access, M27*2 thread connection, insert depth 300mm