Low halogen low smoke characteristics, when the fire occurs, the spread speed is slow, low smoke concentration, high visibility, small amount of harmful gas release, easy to evacuate personnel. The corrosion of combustion gas is small, and the damage to equipment is also avoided. The characteristics of low halogen and halogen free make the cable material have great aging resistance and uv resistance and other irradiation resistance, so as to prolong the use of the cable. Product execution standard: GB9330-88Q/WTL11-2003 Rated cable voltage UO/U:450/750V, AC polyolefin UO/U is 0.6/1kV 2. The long-term working temperature of the cable is -20℃-90℃, -40℃-105℃ 3. Bending radius: no less than 6 times of cable diameter for unarmored cables, no less than 12 times of cable diameter for armored or copper belt shielded cables. 1. The cable shall be subjected to power frequency voltage test of 3kV under ambient temperature and shall not break down in 5min. 2. The transmittance of cables should comply with the following table

Outer diameter of cable D(mm) Transmittance (%)≥ Outer diameter of cable D(mm) Transmittance (%)≥
D > 40 70 5 < D 10 or less 50
10 < D 40 or less 60 D 5 or more 40

3. Non-flame retardant cable (flame retardant characteristics): should pass gb12666.5-90 class B bundle combustion test. Single wire and cable vertical combustion test shall pass GB12666.2-904. PH value and conductivity of combustion gas, 754-2pH ≥4.3 conductivity ≤10μS/mm. V. Basic Model and Name:

model The name of the
DLD-KVV Copper conductor low smoke low halogen PVC insulated and sheathed control cable
DLD-KVVP Copper conductor low smoke low halogen PVC insulated and sheathed copper mesh braided shield control cable
DLD-KVV22 Copper conductor low smoke low halogen PVC insulated and sheathed steel tape armored control cable
WLD-KJEG Copper conductor halogen free low smoke crosslinked polyolefin insulated thermosetting sheath control cable
WLD-KJEGP Copper conductor halogen free low smoke crosslinked polyolefin insulated thermosetting sheathed copper screen control cable
WLD-KJEGP2-22 Copper conductor halogen free low smoke crosslinked polyolefin insulated thermosetting sheath copper tape screen block steel tape armored control cable
WLD-KJES Copper conductor halogen free low smoke crosslinked polyolefin insulated thermoplastic sheathed control cable
WLD-KJESP Copper conductor halogen free low smoke crosslinked polyolefin insulated thermoplastic sheathed copper screen control cable
WLD-KJES22 Copper conductor halogen-free low smoke crosslinked polyolefin insulated thermoplastic sheathed steel tape armored control cable
DLD-KSF Copper core low smoke low halogen thermoplastic insulated nitrile thermoplastic sheathed control cable
DLD-KSFP Copper core low smoke low halogen thermoplastic insulated nitrile thermoplastic sheathed copper screen control cable
DLD-KSFP2-22 Copper core low smoke low halogen thermoplastic insulation nitrile thermoplastic body sheath copper tape screen block steel tape armored control cable

Code, Name and Meaning:

project Code name meaning
A series of codes DLD
WLD
K
Low smoke low halogen
Low smoke zero halogen
Control cable
Insulation materials V
J
E
F
Polyvinyl chloride (PVC)
crosslinking
polyolefin
Nitrile thermoplastics
Sheath material V
G
S
Polyvinyl chloride (PVC)
Thermosetting jacket
Thermoplastic jacket
Shielding materials P
P2
Copper mesh or tinned copper mesh
Copper/plastic composite tape
Armoring materials 22
32
Steel belt
Fine wire
Conductor type A
B
R
D.u strands of conductor
Seven stranded conductors
Stranded conductor

Vii. Production scope:

Cross section was 0.5 1.0 1.5 2.5 4 6 10 16 25
some 2-81. 2-81. 2-81. 2-50 2-37 2-20 2-19 2-14 2-10

Note: other cables of the same size and material can be produced according to customer's requirements.