Wear resistant thermocouple is the temperature measurement protection tube in the field of high temperature and wear resistance in power plants, cement plants, chemical smelters and so on. Electrical outlet: M20×1.5, NPT1/2 Wear-resistant head hardness: HRC60-65 Protection grade: IP65
Wear-resistant thermocouple protection tube type and performance:
type |
Code name |
The performance characteristics of |
Measuring range ℃ |
Outside diameter d (mm) |
Applicable occasions |
Stainless steel spraying |
NP |
wear-resisting |
0 ~ 800 |
Φ Φ 16, 22 |
Cement, Pulverized coal, Fluidized bed, Fluidized bed, The cement rotary kiln |
Stainless steel reinforcement |
Q |
longevity |
0 ~ 800 limit of 0 ~ 1050 |
Φ 22 ~ Φ 30 |
|
carbide |
NH10 |
Wear resistance, high temperature resistance |
0 ~ 1100 |
16 ~ Φ Φ 34 |
|
High temperature alloy |
NH12 |
Wear resistance, corrosion resistance, high temperature resistance, good strength |
0 ~ 1200 |
Φ Φ of 20 ~ 25 |
|
High temperature alloy |
NH13 |
Wear resistance, corrosion resistance, high temperature resistance, good performance |
0 ~ 1300 |
Φ 22 |
|
High chromium cast iron |
G |
Wear resistance, corrosion resistance, large outer diameter |
0 ~ 1050 |
Φ 32 ~ Φ 38 |
Wear-resistant thermocouple model and specification
model |
Degree, |
Temperature range: ℃ |
Nominal pressure |
The velocity |
specifications |
|
d |
L * L |
|||||
WRN-230N |
K |
0-800. |
100 mpa or less |
100 m/s or less |
Ф 16 |
300×150 |
WRE-230N |
E |
0-600. |
||||
WZP-230N |
Pt100 |
- 200 ~ 500 |
||||
WRN-630N |
K |
0-800. |
30 mpa or less |
80 m/s or less |
Ф 15 |
|
WRE-630N |
E |
0-600. |
||||
N WZP2 WZP - 630, 630 n |
Pt100 |
- 200 ~ 500 |
Wear-resisting thermocouple, wear-resisting thermal resistance type selection spectrum
WZ |
|
The thermal resistance |
||||
WR |
|
thermocouple |
||||
|
Temperature sensing element |
|
||||
C |
|
Cu50 (Thermal resistance) |
||||
P |
|
Pt100 (Thermal resistance) |
||||
N |
|
Nickel-chromium nickel-silicon K |
||||
E |
|
Nickel chromium copper nickel E |
||||
|
The connection form |
|
||||
2 |
|
Fixed screw thread |
||||
3 |
|
Activities of the flange |
||||
4 |
|
Fixed flange |
||||
6 |
|
Secure threaded tapered protection tube |
||||
|
Junction box form |
|
||||
2 |
|
Spray type |
||||
3 |
|
Water proof |
||||
|
Protective tube diameter |
|
||||
0 |
|
16 |
||||
1 |
|
12 |
||||
T |
φ 18, φ 20, φ 22, φ 25, φ 28, φ 32 |
custom |
||||
Wear-resisting labeled |
NM |
|||||
Wear-resistant head material |
|
|||||
-SN |
Cement plant |
|||||
-DC |
Power plant is special |
|||||
-LM |
Plasma spraying |
|||||
-CM |
High chromium cast iron |
|||||
-KM |
K's alloy |
|||||
Special material |
|
|||||
Use occasions |
When ordering wear-resisting thermocouple, wear-resisting thermal resistance, customers must determine the use of industrial and mining occasions, the use of temperature, easy for manufacturers to choose the correct wear-resisting head material |