The product has cold resistance, soft, wear resistance, oil resistance and other characteristics, suitable for the rated AC voltage up to and including 0.6/1kV cold resistance, oil resistance and other special requirements of mobile electrical connection cable, the product has been widely used in metallurgy, electric power, ships, automobile manufacturing and other industries.
Ii. Product standard Q/HL009-2004. Flame retardant performance test in accordance with GB12666-90
Three: use characteristics
1. Ac rated voltage: U0/U 0.6/1kV Z.UI High operating temperature: 105℃ Z.ui Low ambient temperature: -40℃ for fixed installation
2. The temperature of cable installation and laying should not be lower than -25℃.
3. The allowable bending radius of the cable is 12 times of the cable diameter
Four: Basic model and name
Table 1 Model name
YVFR Nitrile insulated and jacketed power flexible cable
YVFRP nitrile insulated and jacketed copper braided shielded power cable
Zr-yvfr flame retardant nitrile insulated and sheathed power flexible cable
Zr-yvfrp flame retardant nitrile insulation and sheath copper braided shield flexible power cable
YVFPR nitrile insulated and sheathed flexible cable
YVFRP2 Nitrile insulated and sheathed copper foil shielded power flexible cable
YVFRB power soft flat cable with nitrile insulation and sheath
YVFRPB nitrile insulated and jacketed copper braided shield soft flat power cable
YVFB nitrile insulated and jacketed mobile flat cable
YVFPB nitrile insulated and jacketed copper braided shield mobile flat cable
YVFP2B Nitrile insulated and sheathed copper foil shielded mobile flat cable
Zr-yvfrpb flame retardant nitrile insulated and jacketed copper braided shield mobile flat cable cable
Nh-yvfr Refractory nitrile insulated and sheathed power flexible cable
Nh-yvfrp refractory nitrile insulation and sheath copper braided shield power cable
KYVFR Nitrile insulated and jacketed control flexible cable
KYVFRP nitrile insulated and sheathed copper braided shield control flexible cable
Zr-kyvfr flame retardant nitrile insulated and jacketed control flexible cable
Zr-kyvfrp flame retardant nitrile insulated and sheathed copper braided shield control flexible cable
KYVFPR nitrile insulated and jacketed control flexible cable
KYVFRP2 Nitrile insulated and sheathed copper foil shielding control flexible cable
YVFP nitrile insulated and jacketed shielded power cable
KYVFP nitrile insulated and jacketed copper braided shield control cable
Zr-kyvfp flame retardant nitrile insulated and sheathed control cable
Zr-kvfp2 flame retardant nitrile insulated and sheathed copper foil shielding control cable
YVFP2 Nitrile insulated and sheathed copper foil shielded power cable
KYVFB nitrile insulated and jacketed control flat cable
Zr-yffb flame retardant nitrile composite insulation and sheath mobile flat flexible cable
Zr-yffpb flame retardant nitrile composite insulation and sheathed copper wire shielding mobile flat flexible cable
YFFB nitrile composite insulated and jacketed mobile flat flexible cable
YFFBP nitrile composite insulated and jacketed copper wire shielding mobile flat flexible cable
YFFRB nitrile composite insulation and sheath mobile flat flexible cable
YFFRBP nitrile composite insulated and jacketed copper wire shielding mobile flat flexible cable
YFF nitrile compound insulated and sheathed cable
YFFP nitrile compound insulated and sheathed copper wire shielded cable
Table 2 Code Name Meaning YVF Nitrile cable series P copper braided shield R Multi-stranded conductor B flat cable
Six: main technical indicators
1. Dc resistance of finished cable conductor (Class R) (in accordance with GB3956) refer to Table 2 in Appendix A.
The insulation resistance is not less than 50M ω /KM at 2.20 ° C.
3. Finished cable withstands ac 50HZ3.5 kV /5min voltage test without breakdown.