sales@anhuitiankang-group.com
Home      Products     Cables     Heating cable       Composite cable heat tracing pipe
  • Composite cable heat tracing pipe

Composite cable heat tracing pipe

Introduction of heat tracing sampling composite pipe and cable

Heat tracing sampling composite pipe and cable is an important component in the monitoring system. It is composed of a group of corrosion-resistant high-performance resin conduit, high-temperature constant power electric heating belt or self limiting electric heating belt and compensation cable. It is added with imported raw material insulation layer and coated with polyethylene or polyvinyl chloride sheath after z.ui. The constant power electric heating band adopts platinum resistance temperature probe to control the temperature. The automatic temperature limiting function of self temperature limiting electric heating band can ensure that a certain temperature is maintained in the sampling tube, so as to ensure that the collected samples are consistent with the initial value as much as possible, and z.ui finally ensures the continuity of the monitoring system. Accurately collect the sample gas. According to different ambient temperatures, appropriate tracking belt, compensation line, power line, etc. can be used. It can also be added according to user requirements.

Technical parameters of heat tracing sampling composite pipe and cable

1. Supporting heat pipe: made of perfluorooctane sulfonic acid, FEP and polytetrafluoroethylene;; The outer diameter is 6mm, 8mm and 10mm, with single pipe, double pipe and three cores.

2. Companion belt: Mi heating cable, constant power and automatic temperature control.

3. Outer diameter of heat tracing pipe: DN32 2 mm, dn38 2 mm, dn42 2 mm, dn45 2 mm

4. The heat tracing temperature of sampling gas is 70 ℃ / 85 ℃ / 100 ℃ / 120 ℃ / 150 ℃ / 180 ℃ / 220 ℃.

5. Insulation layer: high temperature resistant rock wool and glass wool.

6. Sheath layer: Black polyvinyl chloride / polyvinyl chloride / polyethylene wear-resistant layer, flame retardant / waterproof / high temperature / corrosion resistant.

Installation rules of heat tracing sampling composite pipe

Electrical index

1. Rated voltage: 220VAC

2. The self temperature limiting pipeline z.ui has a large heating length of 100 ~ 120m

3. The self temperature limiting pipeline is equipped with a circuit breaker with a current value of 30a

4. One circuit of heat tracing system.

Thermal index

1. Under the condition of - 20 ℃ ambient temperature and 15m / s wind speed, the temperature in the pipe shall be maintained at 40 ~ 50 ℃.

2. The sampling tube can resist the corrosion of various acid and alkali media, and the compressive strength is 1.0MPa without leakage.

3. The sampling tube can work for a long time at a temperature of < 200 ℃.

Installation index

1. The z.ui small curvature radius of the composite pipe is 0.5m.

2. Z.ui low installation temperature - 20 ℃ (take appropriate measures at - 30 ℃ ~ - 40 ℃).

3.z.ui small fixed distance: 2m vertically and 4m horizontally.

Precautions for installation of heat tracing sampling composite pipe

It is strictly prohibited to twist and drag on the ground during construction. The pipe head sheath can be removed only after the contact is installed. The end of the tracing band shall be closed to prevent short circuit of two wires of the tracing band and burning of the tracing band. The shielding layer of the tracing band must be grounded to prevent electric shock. Special intermediate junction box or power junction box shall be used at one end of the power supply to avoid potential accidents. Install leakage protector of distribution switch.


No previous NEXT:Heating cable

INQUIRY

Email